| Sign In | Join Free | My futurenowinc.com |
|
Brand Name : COENG
Model Number : HD8000
Certification : CE
Place of Origin : China
MOQ : 1
Payment Terms : L/C,T/T,Western Union
Supply Ability : 20000sets/year
Delivery Time : 10-30working days
Packaging Details : Wooden Case
Rated voltage of grid side : 2: 1900V 3: 3300V 6: 6600V A: 10kV
Rated voltage of motor side : 3: 3300V 6: 6600V A: 10kV
Power : 10: 10MVA
Rectification method : P: PWM D: Diode basic rectification
Common bus rectification method : Blank: single rectification 2: double rectification
Common bus inverter method : Blank: single D: double inverter T: triple inverter
HD8000 series VFD is a high-power drive system includes AC-DC-AC comverter and DC-AC common DC bus multi-axis motor drive unit. The maximum power can reach 30MVA for single machine and 60MVA for parallel operation. Its modular hardware and engineering software design concept enables it to operate for various complex conditions.
HD8000 series VFD adopts presspack IGCTand Diode as well as liquid cooling method, the whole machine meets the protection level IP54 and it has super environmental adaptability, high reliability, excellent heat dissipation performance and small volume, there are two-quadrant and four-quadrant rectification solutions.
| HD8000 Technical Specifications | ||||||||||||||
| HD8000 | 3306 | 3308 | 3310 | 3312 | 2624 | AA30 | 6640 | AA60 | ||||||
| R Basical ectification | Input voltage | 3300V | 1900V | 10kV | 6600V | 10kV | ||||||||
| Input frquency | 45Hz-66Hz | |||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥99% | |||||||||||||
| Power factor | ≥0.95 (Rated current, equipped with 2% AC input reactor) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| RecPWM tification | Input frquency | 45Hz-66Hz | ||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥98.5% | |||||||||||||
| Power factor | adjustable (default 1) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| Inverter | Output voltage | 3300V | 6600V | 10kV | 6600V | 10kV | ||||||||
| Max output frequency | 110Hz | |||||||||||||
| Speed stable accuracy | OLVC: 0.01%, CLVC: 0.01% | OLVC: 0.01%, CLVC: 0.01% | ||||||||||||
| Speed pulse | OLVC: 0.2%, CLVC: 0.1% | OLVC: 0.4%, CLVC: 0.2% | ||||||||||||
| Start torque | OLVC: 150%, CLVC: 200% | OLVC: 130%, CLVC: 150% | ||||||||||||
| Torque control | V/F: Yes, OLVC: Yes, CLVC: Yes | V/F: Yes, OLVC: Yes, CLVC: Yes | ||||||||||||
| Torque accuracy | OLVC: 5%, CLVC: 2% | OLVC: 5%, CLVC: 2% | ||||||||||||
| Torque response time | OLVC: 5ms, CLVC: 5ms | OLVC: 5ms, CLVC: 5ms | ||||||||||||
| Rotating response time | OLVC: 100ms, CLVC: 100ms | OLVC: 150ms, CLVC: 150ms | ||||||||||||
| Dynamic drop equivalent | OLVC: 0.5%*s, CLVC: 0.25%*s | OLVC: 1%*s, CLVC: 0.5%*s | ||||||||||||
| Overload | 110%@rated current, 120%@rated current 60s | |||||||||||||
| Environment | Temperature | inlet temperature ≤40 | ||||||||||||
| Altitude | ≤4000m (2000m~4000m de-rating) | |||||||||||||
| Mechanical Data | IP protection | IP54 | ||||||||||||
| Cooling | Water cooling | |||||||||||||
| Anti corrosion | C4-M | |||||||||||||
| Module | Grid Voltage | Motor Voltage | Power | RatedI | Max f | Size (W*D*H) (mm) | Note | |||||||
| HD8000-3306 | 3300V | 3300V | 6MVA | 1050A | 110Hz | 4600*1300*2200 | Contains water cool cabinet | |||||||
| HD8000-3308 | 8MVA | 1400A | ||||||||||||
| HD8000-3310 | 10MVA | 1750A | ||||||||||||
| HD8000-3312 | 12MVA | 2100A | ||||||||||||
| HD8000-2624 | 1900V | 6600V | 24MVA | 2100A | 7800*1300*2200 | |||||||||
| HD8000-AA30 | 10kV | 10kV | 30MVA | 1750A | 10600*1300*2200 | |||||||||
| HD8000-6640 | 6600V | 6600V | 40MVA | 3500A | 15600*1300*2200 | |||||||||
| HD8000-AA60 | 10kV | 10kV | 60MVA | 3500A | 21200*1600*2200 | |||||||||
|
|
High-Power Frequency Converter Features Ultra-Fast 5ms Torque Response for Demanding Applications Images |